Littelfuse Resettable Fuses (PPTC): When They Fit and When They Don't
A fuse that forgives the first fault
Most fuses have one job and one life: a fault current melts the element, the circuit opens, and the fuse is replaced. A resettable fuse, a PPTC device, is built for a different story: the fault current heats the device, its resistance rises sharply, the current falls to a small leakage level, and when the fault clears and the device cools, it returns to a low-resistance state and the circuit works again without a replacement.
That forgiveness is genuinely useful, and genuinely misunderstood. A PPTC device is not a fuse that never needs attention, and it is not a fuse that fits any circuit where a one-time fuse would fit. It trips more slowly, it never fully opens the circuit, and its behaviour changes with temperature. Each fact decides whether it fits.
What a PPTC device actually is
A PPTC device is a polymeric positive temperature coefficient device. Inside it is a conductive polymer material whose resistance rises sharply when it gets hot. In normal operation the device is cool, its resistance is low, and the circuit current flows through it with only a small voltage drop. When a fault drives a large current through it, the polymer heats, its resistance climbs sharply, and the current falls to a small leakage level.
- In normal operation it is a low-resistance path. The device sits in series with the load, and the circuit works as if the device were a short piece of wire with a small resistance.
- During a fault it becomes a high-resistance path. The heat of the fault current drives the resistance up, and the current falls. The device limits the current rather than opening the circuit.
- After the fault it can reset. When the fault is removed and the device cools, its resistance falls again and the circuit returns to normal operation, with no replacement needed.
Hold current and trip current: the two numbers that define the device
A PPTC device is defined by two current ratings, and confusing them is the most common selection mistake.
- Hold current is the current the device will carry without tripping. At or below the hold current, in the stated conditions, the device stays in its low-resistance state and the circuit works normally. The highest normal current the circuit draws must sit below the hold current, with margin, or the device will trip during normal operation.
- Trip current is the current at which the device is guaranteed to trip. At or above the trip current, in the stated conditions, the device will move to its high-resistance state within a stated time. A fault current between the two may or may not trip the device.
- The gap between the two is not a defect. The device needs a band between "definitely carries" and "definitely trips", because manufacturing spread and temperature move the boundary.
- Both ratings are stated at a stated temperature. Hold current and trip current change with ambient temperature, which is covered below, so the check has to be made at the temperature the device will actually see.
Start from the circuit: the hold current has to sit above the highest normal current, and the trip current below the lowest fault current the circuit must be protected against. For how to read the technical document, see How to Read a Datasheet Before You Request a Quote.
Trip time: how fast the device acts
A PPTC device does not trip instantly: it trips because the fault current heats it, and heating takes time. A large fault current trips it quickly, while a fault current only slightly above the trip current trips it slowly.
- Trip time falls as fault current rises. The technical document shows this relationship as a curve, and the check is to read the trip time at the fault current the circuit may actually see, not at the largest fault current the document lists.
- A small overload can take a long time to trip. A fault current just above the trip current may take a long while to trip the device, and during that time the circuit carries more current than it should.
Name the fault before naming the device: what fault current will the circuit see, and how long can it carry it?
Reset: what has to happen before the device comes back
A PPTC device resets only when two conditions are met.
- The fault must be gone. As long as the fault is still present, current still flows through the high-resistance device, the device stays hot, and it stays tripped. Removing the power, or removing the fault, is what lets the device cool.
- The device must cool down. Even after the fault is gone, the device needs time to cool before its resistance falls back to its low value. If power is reapplied while it is still hot, it may trip again immediately.
Ask before ordering: when this device trips, who or what removes the fault, and how long will the device have to cool? If nobody removes the fault, the device will sit tripped and the circuit will stay down.
PPTC devices and one-time fuses: the real differences
A PPTC device and a one-time fuse are often treated as interchangeable. They are not, and the differences decide the choice.
- A one-time fuse opens the circuit completely. When it blows, the current falls to nothing, and the circuit is fully disconnected from the source. A PPTC device in its tripped state still passes a small leakage current, and the circuit is never fully disconnected.
- A one-time fuse acts faster on a large fault. A fuse element melts quickly under a large fault current, while a PPTC device has to heat up first.
- A one-time fuse has to be replaced after it acts. Every trip is a service visit, a spare part, and downtime. A PPTC device resets itself once the fault is gone, which is its whole advantage on circuits where faults are occasional and temporary.
For the one-time fuse checks, see Buying Littelfuse Fuses: Match the Fuse to the Circuit.
Where a PPTC device fits
A PPTC device fits where its strengths are the ones the circuit needs.
- Faults that are occasional and temporary. A short circuit caused by a pinched cable, a connector fault, or a momentary overload is the classic case: the device trips, the fault is cleared, and the circuit works again without a service visit.
- Circuits where a service visit is expensive. Equipment in a remote location or a sealed enclosure benefits most, because every blown fuse is a visit or a return.
- Circuits that can tolerate a slow trip and a leakage current. The load has to survive the fault current until the device trips, and tolerate the small leakage current while it is tripped.
- Low-voltage circuits. PPTC devices are commonly used on low-voltage power inputs, where the tripped-state voltage is modest.
Where a PPTC device does not fit
- Where the circuit needs a fast and complete break. If the fault must be cleared quickly and the circuit must be fully disconnected from the source, a PPTC device is the wrong part. It trips slowly, and it never fully opens. A one-time fuse, or a breaker that opens completely, is the part for that job.
- Where the fault current is very large. A PPTC device has a maximum fault current it can interrupt safely, stated in the technical document. Large fault currents belong to fuses and breakers built for them.
- Where the voltage in the tripped state is high. In its tripped state the device has most of the supply voltage across it, and it must be rated for that voltage. A circuit whose supply voltage exceeds the device rating cannot use the device, however well the current ratings match.
- Where the load cannot tolerate the leakage current. A load that must be fully de-energised cannot be protected by a part that never fully opens.
- Where safety isolation is required. A PPTC device is a current limiter, not an isolation device. Where a standard or a safety rule requires the circuit to be physically disconnected after a fault, the disconnection has to come from a fuse, a breaker, or a switch that opens.
If any of these cases describes the circuit, the PPTC device is not the right protection.
Temperature: the rating that moves with the weather
Hold current and trip current are not fixed numbers: they move with ambient temperature.
- Hold current falls as temperature rises. A device that carries the load comfortably on a cool bench may trip in a warm enclosure, because the warmer the device starts, the less extra heat it takes to trip it. Check the hold current at the highest temperature the device will actually see.
- Trip current falls with temperature too. A device in a warm environment trips at a lower fault current than the same device in a cool one.
- Self-heating counts as well. The device heats itself slightly in normal operation, because its own resistance turns a small part of the load current into heat. In a warm enclosure, that self-heating adds to the ambient temperature.
Voltage rating, package, and mounting
A PPTC device that is right on current and wrong on voltage, package, or mounting is still the wrong device.
- Voltage rating is a limit, not a target. The device must be rated for the highest voltage it will see in its tripped state, which is the supply voltage. A device with the right current ratings and the wrong voltage rating cannot be used on that supply.
- Size is a parameter, not a detail. Size affects how much fault current the device can handle and how quickly it trips and resets, and it has to fit the space on the board.
- Mounting decides the trip and the reset. A device mounted near other hot parts runs warmer, trips sooner, and resets more slowly. The thermal environment is part of the selection.
- Check the package in the part number. The part number carries the package and mounting form, and it should be checked against the board footprint before the order is placed. A part number copied without its package detail is an order for a family, not a part.
Checklist before you request a quote
- Circuit known — Highest normal current, including its variations, and the lowest fault current the circuit must be protected against.
- Hold current checked — Above the highest normal current, with margin, at the highest temperature the device will see.
- Trip current checked — Below the lowest fault current the circuit must be protected against, at the temperature the device will see.
- Trip time checked — Read from the curve at the real fault current, and the circuit can survive the fault for that long.
- Reset conditions checked — The fault will be removed, and the device will have time to cool before the circuit is expected to work again.
- Fit decided — The fault is occasional and temporary, and no fast complete break or safety isolation is required.
- Voltage rating checked — Covers the supply voltage the device will see in its tripped state.
- Temperature checked — Ratings read at the temperature the device will see in service, including self-heating and enclosure warmth.
- Package and mounting checked — Matched to the board footprint, with the thermal environment considered.
- Part number written in full — Complete with every character, copied from the technical document.
When the list is complete, the request can be written in one pass. Before sending it, read the supplier reply against the same list, as explained in How to Read a Quote Reply: Four Lines to Check. That request goes to the inquiry page — written in full, so the answer can be checked line by line.
FAQ
How do I choose the hold current for my circuit?
Start from the highest current the load draws in normal operation, including its regular variations, and choose a device whose hold current sits above it with margin, at the highest temperature the device will see. Then check the trip current against the lowest fault current the circuit must be protected against, and check the trip time at that fault current.
My circuit is in a warm enclosure. Will the same PPTC device still work?
That has to be checked, not assumed. Hold current falls as temperature rises, so a device that carries the load on a cool bench may trip in a warm enclosure. Read the hold current and trip current at the highest temperature the device will actually see, and re-check the whole list at that temperature.
The fault in my circuit is permanent until someone fixes it. Is a PPTC device still useful?
It depends on what the device is being asked to do. While the fault is present, the device stays tripped and the circuit stays down, and it will only reset after the fault is removed and the device cools. If the circuit recovers by itself once the fault is cleared, the device fits. If the fault will never be cleared, the circuit needs a part that fails safe on its own.
When should I choose a one-time fuse instead of a PPTC device?
Choose the one-time fuse when the circuit needs a fast and complete break, when the fault current is very large, when the load cannot tolerate any leakage current while the protection is active, or when safety isolation is required after a fault. Choose the PPTC device when the fault is occasional and temporary and the circuit can tolerate a slower trip and a small leakage current.